This site uses cookies.
Some of these cookies are essential to the operation of the site,
while others help to improve your experience by providing insights into how the site is being used.
For more information, please see the ProZ.com privacy policy.
This person has a SecurePRO™ card. Because this person is not a ProZ.com Plus subscriber, to view his or her SecurePRO™ card you must be a ProZ.com Business member or Plus subscriber.
English to Russian: IT. From a big manual to DBMS Oracle 11
Source text - English Oracle Flexible Architecture
Optimal Flexible Architecture (OFA) ensures reliable installations and improves software manageability. This feature streamlines the way in which Oracle software installations are organized, thereby simplifying the on-going management of your installations and improves manageability by making default Oracle Database installs more compliant with OFA specifications.
During installation, you are prompted to specify an Oracle base (ORACLE_BASE) location, which is owned by the user performing the installation. You can choose an existing ORACLE_BASE, or choose another directory location that does not have the structure for an ORACLE_BASE directory.
Using the Oracle base directory path helps to facilitate the organization of Oracle installations, and helps to ensure that installations of multiple databases maintain an OFA configuration. During the installation, ORACLE_BASE is the only required input, as the ORACLE_HOME will be defaulted based on the value chosen for the ORACLE_BASE. In addition, Oracle recommends that you set the ORACLE_BASE environment variable in addition to ORACLE_HOME, when starting databases. Note that ORACLE_BASE may become a required environment variable for database startup in a future release.
See Also: Your platform-specific Oracle Real Application Clusters installation guide for more information about specifying an ORACLE_BASE directory
Datafile Access in Oracle Real Application Clusters
All Oracle RAC instances must be able to access all datafiles. If a datafile needs to be recovered when the database is opened, then the first Oracle RAC instance to start is the instance that performs the recovery and verifies access to the file. As other instances start, they also verify their access to the datafiles. Similarly, when you add a tablespace or datafile or bring a tablespace or datafile online, all instances verify access
to the file or files.
If you add a datafile to a disk that other instances cannot access, then verification fails. Verification also fails if instances access different copies of the same datafile. If verification fails for any instance, then diagnose and fix the problem. Then run the ALTER SYSTEM CHECK DATAFILES statement on each instance to verify datafile access
Оптимальная гибкая архитектура (OFA) обеспечивает надежную инсталляцию и повышает управляемость программного обеспечения. Эта функция упорядочивает организацию установленного программного обеспечения, упрощая тем самым непрерывное управление программами, а также и повышает управляемость за счет того, что делает компоненты СУБД Oracle Database, устанавливаемые по умолчанию, более совместимыми с конфигурациями OFA.
Во время инсталляции система запросит указать расположение базы Oracle (ORACLE_BASE), которая принадлежит пользователю, производящему инсталляцию. Можно выбрать существующее значение ORACLE_BASE, или же выбрать иное расположение каталога, который имеет структуру, отличную от ORACLE_BASE.
Использование пути к базе Oracle помогает упростить организацию инсталляций в СУБД Oracle, а при установке нескольких баз обеспечивает то, что данная установка будет поддерживать конфигурацию OFA. Во время инсталляции требуется ввести только значение переменной ORACLE_BASE, значение же ORACLE_HOME будет установлено по умолчанию на основании значения, установленного для ORACLE_BASE. Кроме того, при запуске баз данных рекомендуется установить значение переменной среды ORACLE_BASE , в дополнение к ORACLE_HOME. Следует обратить внимание, что ORACLE_BASE может стать необходимой переменной среды для запуска базы данных в последующих версиях СУБД.
См. также: Руководство по установке Oracle Real Application Clusters для конкретной операционной системы, где изложена более подробная информация, касательно каталога ORACLE_BASE.
Доступ к файлам данных в среде Oracle Real Application Clusters.
Все экземпляры Oracle RAC должны иметь доступ ко всем файлам данных. Если при открытии базы данных требуется восстановление файла данных, в этом случае первым будет запущен тот экземпляр Oracle RAC, который производит восстановление и проверяет доступ к файлу. При запуске других экземпляров, они также будут проверять доступ к файлам данных. Аналогично, при добавлении табличного пространства или файла данных, или же при переводе их в оперативное состояние, все экземпляры проверяют доступ к файлу или файлам.
При добавлении файла данных на диск, к которому другие экземпляры доступа не имеют, проверка будет неудачной. Проверка также даст отрицательный результат, если экземпляры будут иметь доступ к разным копиям одного и того же файла данных. Если для какого-либо экземпляра проверка не проходит, следует провести диагностику и устранить проблему. После чего следует выполнить команду ALTER SYSTEM CHECK DATAFILES на каждом экземпляре для проверки доступа к файлам данных.
English to Russian: Electronics. From the Fill Level Limit Switch Nivotester FTL 325 N manual
Source text - English Signal transmission
The inherently safe input of the Nivotester FTL 325 N limit switch is galvanically separated from the network and from the output.
The Nivotester provides the Liquiphant M and Liquiphant S (high temperature) sensing elements with an FEL 56 and 58 electronic application or a sensor specified according to EN 50227 (DIN 19234; NAMUR) or IEC 60947-5-6 over a two-wire line with direct current. A control current is simultaneously transmitted on this supply line.
The control current range is between < 1.2 mA and > 2.1 mA depending on the switching state.
Signal evaluation
The Nivotester measures the control current that is transmitted over the supply line of the sensors, and evaluates them. The relay for the fill level alarm signals whether the sensor is covered or is free and a light-emitting diode indicates the switching state of the relay on the front plate of the Nivotester. Disturbances such as a line interruption or short-circuit are likewise indicated.
Safety switching
Correct selection of the safety switching makes it possible for the relays to always work in quiescent current safety. On the Nivotester, the fault current signal (< 1.2 mA or > 2.1 mA) of the connected sensor of each channel can be set with the DIL switches. As a result, the switching amplifier can be used in the required safety operation in any application.
Quiescent current safety in combination with a fill level limit switch is defined as follows:
• Maximum safety: The relay releases, when the switching point is exceeded (sensor covered), a malfunction appears or the network voltage is lost.
• Minimum safety: The relay releases, when the switching point is exceeded (sensor free), a malfunction appears or the network voltage is lost.
Note!
Please refer to the Functional Safety Manual SD 161F for applications with functional safety requirements according to IEC 61508 / IEC 61511 (SIL).
Translation - Russian Передача сигнала
Входная цепь повышенной безопасности уровнемера Nivotester FTL 325 N гальванически изолирована от сети и от выходной цепи.
Уровнемер Nivotester обеспечивает измерительные датчики Liquiphant M и Liquiphant S (высокотемпературный) электронным преобразователями FEL 56 и 58 или датчиком, соответствующим требованиям стандарта EN 50227 (DIN 19234; NAMUR) или IEC 60947-5-6, который подключается при помощи двухпроводной линии постоянного тока. Управляющий сигнал передается одновременно по этой линии питания.
Управляющий сигнал имеет диапазон от < 1.2 мА и до > 2.1 мА, в зависимости от коммутационного состояния.
Оценка характеристик сигналов
Уровнемер Nivotester измеряет управляющий сигнал, который передается по линии питания и оценивает его. Реле уровня заполнения дает сигнал, покрыт ли датчик жидкостью или нет, а светодиод на передней панели Nivotester показывает коммутационное состояние реле. Также этот светодиод отражает разного рода нарушения в работе, такие как обрыв линии или короткое замыкание.
Предохранительное выключение
Правильный выбор предохранительного выключения делает возможным постоянную работу реле в режиме безопасности собственного потребляемого тока. В устройстве Nivotester сигнал тока повреждения (< 1.2 мА или > 2.1 мА) от подключенного датчика на каждом канале может быть установлен при помощи переключателей с двухрядным расположением выводов. В результате усилитель переключения может использоваться в требуемой операции обеспечения безопасности в любой сфере применения.
Безопасность потребляемого тока в сочетании с отключением по уровню заполнения может быть установлена в следующих режимах.
• Максимальная безопасность: реле отпускается при превышении точки выключения (датчик покрыт жидкостью), появлении неисправности или отключении напряжения в сети.
• Минимальная безопасность: реле отпускается при превышении точки выключения (датчик не покрыт жидкостью), появлении неисправности или отключении напряжения в сети.
Внимание!
Для областей применения с требованиями функциональной безопасности, соответствующими IEC 61508 / IEC 61511 (SIL) следует обратиться к Инструкции по технике безопасности SD 161F.
English to Russian: Oil Equipment. From the Dead-Weight-Hydraulic Filter Press manual
Source text - English DEAD-WEIGHT-HYDRAULICS PRESSURE SOURCE
The Dead-Weight-Hydraulic Filter Press is a Series 300 Filter Press equipped with a Dead-Weight Hydraulic Assembly. Refer to Fig. 3. The Dead Weight Hydraulic Assembly is shown in Fig. 4. Follow this procedure to pressurize the filter press with the deadweight-hydraulic pressure source:
1. Fill the water reservoir and cylinder of the dead-weight assembly to the top with clean fresh water.
2. Open the bleed-off valve and place the piston, with the weight attached, in the cylinder. Allow the piston to travel full stroke.
3. Refill the reservoir with clean, fresh water and close the bleed-off valve.
4. Set the unit in place on the filter press frame and tighten the attaching set screws, if not previously attached.
5. Connect the air hose from the dead-weight assembly to the top cap pressure inlet, if not previously attached.
6. Raise the weight to the top of its stroke and allow it to settle. In about two-thirds of the stroke, the delivery pressure gauge will indicate 100 psi.
7. Lift the dead weight back to the top of the stroke. Start the timing of the test when the weight is released. One stroke of the piston will allow a maximum filtration loss of approximately 30 ml.
Translation - Russian ГРУЗОПОРШНЕВОЙ ГИДРАВЛИЧЕСКИЙ ИСТОЧНИК ДАВЛЕНИЯ
Грузопоршневой гидравлический фильтр-пресс представляет собой фильтр-пресс серии 300, оборудованный гидравлическим грузопоршневым блоком. См. Рис.3. Гидравлический грузопоршневой блок показан на Рис.4. Для подачи давления на фильтр-пресс с грузопоршевым источником давления необходимо выполнить описанные ниже операции.
1. Наполнить водный резервуар и цилиндр грузопоршневого блока чистой водой до верхнего уровня.
2. Открыть сливной клапан и установить поршень с закрепленным на нем грузом в цилиндр. Дать поршню переместиться на полный ход.
3. Снова наполнить резервуар чистой свежей водой, и закрыть сливной клапан.
4. Если блок не был установлен ранее, установить его на раму фильтр-пресса и затянуть крепежные винты.
5. Если воздушный шланг не подключен, его следует подключить к грузопоршневому блоку и впуску на верхней крышке.
6. Поднять груз в верхнюю точку и подождать, пока он примет устойчивое положение. Когда груз пройдет примерно две третьих своего хода, манометр на стороне нагнетания покажет давление 100 фунтов на кв.дюйм.
7. Поднять груз в верхнее положение. Так только груз будет отпущен начать отсчет времени испытания. Один ход поршня допускает максимальные фильтрационные потери приблизительно до 30 мл.
Adobe Acrobat, Adobe Illustrator, Adobe Photoshop, Frontpage, Microsoft Excel, Microsoft Word, Adobe Acrobat, MS Excel, MS Word, Powerpoint, SDLX, Trados Studio
I represent a group of freelance Russian native translators located in Russia.
We provide high quality translations made by translators that are professionally qualified, native speakers and specialists in the area of the material they translate.
We have our own Programmist Russian Translations company.
Programmist Russian Translations offers you a variety of English-Russian translation services.
Programmist Russian Translations is located in Belgorod, Russia.
The company has been in translation business since 1992 and has regular customers both in Russia and in the USA, Canada, Singapore and other countries.
Programmist Russian Translations has a small but dedicated team of professionals. We all are Russian native speakers. This is the most important reason why we do translations only in these two languages.
Keywords: technical, manual, computer, software, hardware, Trados, html, literature, history, military. See more.technical,manual,computer,software,hardware,Trados,html,literature,history,military,tourism,web,site,books. See less.